DIMM Marketplace ↗ (opens in a new tab)
The balance: 5-in-1 for seasonal variations

ECOMIX® A

In short: ECOMIX® A reduces hardness, iron, manganese and ammonium, and cuts organic matter by 50%. It handles seasonal variations in water composition.

Buy ECOMIX® A on DIMM (opens in a new tab)12 L half bag (opens in a new tab)Compare the 3 resins
5-in-1problems treated in one step
35g CaCO₃/L exchange capacity
5 yearsservice life
50 %organic matter reduction

When to choose ECOMIX® A?

  • Well or mains water with moderate seasonal variations
  • Organic matter present but moderate (50% reduction)
  • Good capacity / versatility trade-off for homes and small commercial sites

What it treats

Hardness up to 750 ppm CaCO₃, iron up to 15 mg/L, manganese up to 3 mg/L, ammonium up to 4 mg/L, natural organic matter up to 20 mg O₂/L (50 % reduction).

Operating conditions

  • Service flow rate: 20–25 m/h; backwash: 10–15 m/h
  • Bed depth: 500 mm minimum, 800 mm recommended; freeboard ≥ 40%
  • Salt dose: 100 g/L (8–10% brine); 150 g/L with potassium chloride
  • pH 5 to 9, TDS < 4,000 mg/L, active chlorine < 1 mg/L
  • Packaging: 25 L bag or 12 L half bag

Certification: ACS · NSF. ECOMIX® A and C are ACS certified (compatibility with drinking water) and NSF certified (NSF/ANSI 44, NSF/ANSI/CAN 61, NSF/ANSI 372, Gold Seal). ECOMIX® P is PZH certified. Before any installation intended for drinking water, check the certificate that applies to the product supplied.

Real results

Raw water → treated water

Grammene (Belgium)

Hardness516 → 25 ppm
Iron2.9 → 0.178 mg/L
Ammonium2.8 → 0.4 mg/L

Pančevo (Serbia)

Hardness534 → 14 ppm
Iron2.2 → 0.16 mg/L
Ammonium1.3 → 0.05 mg/L

Vattenprov (Sweden)

Hardness463 → 28 ppm
Manganese0.65 → 0.014 mg/L
Ammonium0.84 → 0.3 mg/L

Frequently asked questions

Do I need chemicals or a resin cleaner to regenerate ECOMIX®?

No. Only salt tablets are needed. Resin cleaners must not be used: they can severely reduce ECOMIX® efficiency.

Should I oxidise or aerate the water before ECOMIX®?

No, it is even discouraged. ECOMIX® works best when raw water is fed directly, without oxidative pre-treatment (aeration, chlorination). If oxidation is unavoidable, provide a multimedia sediment filter and an activated carbon filter to remove residual chlorine.

What is the service life of ECOMIX®?

3 years for ECOMIX® P and 5 years for ECOMIX® C and A under recommended operating conditions. By comparison, ordinary resin mixes lose up to 30% of their capacity after 20 to 30 regenerations.

How do I calculate the capacity of an ECOMIX® charge?

Volume treated (m³) = ECOMIX® volume (L) × exchange capacity (g CaCO₃/L) ÷ water hardness (ppm CaCO₃). Capacities: C 30, A 35, P 40 g CaCO₃/L. Iron and manganese are not part of the calculation. Example: 50 L of ECOMIX® A with 400 ppm water gives 4.3 m³ between two regenerations.

What tank size and regeneration should I plan?

Recommended bed depth 800 mm (minimum 500 mm), with at least 40% free space above the media. A vessel under 35 in (about 89 cm) high is not recommended. Regeneration in 5 steps: backwash, brine draw, second backwash, fast rinse, brine tank filling. Salt dose: 100 g/L.

See also: ECOMIX® C ECOMIX® P

Ready to solve your water problems?

Find ECOMIX® C, A and P resins on the DIMM marketplace: 25 L bags and 12 L half bags.

Order on the DIMM marketplace (opens in a new tab)