ECOMIX® C
In short: ECOMIX® C treats hardness, iron, manganese, ammonium and natural organic matter (up to 80% reduction) in a single step. It copes even with strong variations in raw water quality.
When to choose ECOMIX® C?
- Well water whose composition varies strongly with the seasons or rainfall
- Coloured water or water loaded with organic matter (oxidisability up to 20 mg O₂/L)
- Installations that need a single resin valid in every situation
What it treats
Hardness up to 750 ppm CaCO₃, iron up to 15 mg/L, manganese up to 3 mg/L, ammonium up to 4 mg/L, natural organic matter up to 20 mg O₂/L (80 % reduction).
Operating conditions
- Service flow rate: 20–25 m/h; backwash: 10–15 m/h
- Bed depth: 500 mm minimum, 800 mm recommended; freeboard ≥ 40%
- Salt dose: 100 g/L (8–10% brine); 150 g/L with potassium chloride
- pH 5 to 9, TDS < 4,000 mg/L, active chlorine < 1 mg/L
- Packaging: 25 L bag or 12 L half bag
Certification: ACS · NSF. ECOMIX® A and C are ACS certified (compatibility with drinking water) and NSF certified (NSF/ANSI 44, NSF/ANSI/CAN 61, NSF/ANSI 372, Gold Seal). ECOMIX® P is PZH certified. Before any installation intended for drinking water, check the certificate that applies to the product supplied.
Raw water → treated water
West Palm Beach, Florida (USA)
Srebrno jezero (Serbia)
Frequently asked questions
Do I need chemicals or a resin cleaner to regenerate ECOMIX®?
No. Only salt tablets are needed. Resin cleaners must not be used: they can severely reduce ECOMIX® efficiency.
Should I oxidise or aerate the water before ECOMIX®?
No, it is even discouraged. ECOMIX® works best when raw water is fed directly, without oxidative pre-treatment (aeration, chlorination). If oxidation is unavoidable, provide a multimedia sediment filter and an activated carbon filter to remove residual chlorine.
What is the service life of ECOMIX®?
3 years for ECOMIX® P and 5 years for ECOMIX® C and A under recommended operating conditions. By comparison, ordinary resin mixes lose up to 30% of their capacity after 20 to 30 regenerations.
How do I calculate the capacity of an ECOMIX® charge?
Volume treated (m³) = ECOMIX® volume (L) × exchange capacity (g CaCO₃/L) ÷ water hardness (ppm CaCO₃). Capacities: C 30, A 35, P 40 g CaCO₃/L. Iron and manganese are not part of the calculation. Example: 50 L of ECOMIX® A with 400 ppm water gives 4.3 m³ between two regenerations.
What tank size and regeneration should I plan?
Recommended bed depth 800 mm (minimum 500 mm), with at least 40% free space above the media. A vessel under 35 in (about 89 cm) high is not recommended. Regeneration in 5 steps: backwash, brine draw, second backwash, fast rinse, brine tank filling. Salt dose: 100 g/L.
Ready to solve your water problems?
Find ECOMIX® C, A and P resins on the DIMM marketplace: 25 L bags and 12 L half bags.
Order on the DIMM marketplace (opens in a new tab)