DIMM Marketplace ↗ (opens in a new tab)
The most versatile: 5-in-1, even when the water changes a lot

ECOMIX® C

In short: ECOMIX® C treats hardness, iron, manganese, ammonium and natural organic matter (up to 80% reduction) in a single step. It copes even with strong variations in raw water quality.

Buy ECOMIX® C on DIMM (opens in a new tab)12 L half bag (opens in a new tab)Compare the 3 resins
5-in-1problems treated in one step
30g CaCO₃/L exchange capacity
5 yearsservice life
80 %organic matter reduction

When to choose ECOMIX® C?

  • Well water whose composition varies strongly with the seasons or rainfall
  • Coloured water or water loaded with organic matter (oxidisability up to 20 mg O₂/L)
  • Installations that need a single resin valid in every situation

What it treats

Hardness up to 750 ppm CaCO₃, iron up to 15 mg/L, manganese up to 3 mg/L, ammonium up to 4 mg/L, natural organic matter up to 20 mg O₂/L (80 % reduction).

Operating conditions

  • Service flow rate: 20–25 m/h; backwash: 10–15 m/h
  • Bed depth: 500 mm minimum, 800 mm recommended; freeboard ≥ 40%
  • Salt dose: 100 g/L (8–10% brine); 150 g/L with potassium chloride
  • pH 5 to 9, TDS < 4,000 mg/L, active chlorine < 1 mg/L
  • Packaging: 25 L bag or 12 L half bag

Certification: ACS · NSF. ECOMIX® A and C are ACS certified (compatibility with drinking water) and NSF certified (NSF/ANSI 44, NSF/ANSI/CAN 61, NSF/ANSI 372, Gold Seal). ECOMIX® P is PZH certified. Before any installation intended for drinking water, check the certificate that applies to the product supplied.

Real results

Raw water → treated water

Deerfield, Wisconsin (USA)

Hardness980 → 30 ppm
Iron1.8 → 0.1 mg/L
Manganese1.7 → 0.01 mg/L

West Palm Beach, Florida (USA)

Iron1.9 → 0.07 mg/L
Oxidisability6.5 → 0.27 mg O₂/L

Srebrno jezero (Serbia)

Hardness1,210 → 16 ppm
Iron9.3 → 0.18 mg/L
Oxidisability12.7 → 3.9 mg O₂/L

Frequently asked questions

Do I need chemicals or a resin cleaner to regenerate ECOMIX®?

No. Only salt tablets are needed. Resin cleaners must not be used: they can severely reduce ECOMIX® efficiency.

Should I oxidise or aerate the water before ECOMIX®?

No, it is even discouraged. ECOMIX® works best when raw water is fed directly, without oxidative pre-treatment (aeration, chlorination). If oxidation is unavoidable, provide a multimedia sediment filter and an activated carbon filter to remove residual chlorine.

What is the service life of ECOMIX®?

3 years for ECOMIX® P and 5 years for ECOMIX® C and A under recommended operating conditions. By comparison, ordinary resin mixes lose up to 30% of their capacity after 20 to 30 regenerations.

How do I calculate the capacity of an ECOMIX® charge?

Volume treated (m³) = ECOMIX® volume (L) × exchange capacity (g CaCO₃/L) ÷ water hardness (ppm CaCO₃). Capacities: C 30, A 35, P 40 g CaCO₃/L. Iron and manganese are not part of the calculation. Example: 50 L of ECOMIX® A with 400 ppm water gives 4.3 m³ between two regenerations.

What tank size and regeneration should I plan?

Recommended bed depth 800 mm (minimum 500 mm), with at least 40% free space above the media. A vessel under 35 in (about 89 cm) high is not recommended. Regeneration in 5 steps: backwash, brine draw, second backwash, fast rinse, brine tank filling. Salt dose: 100 g/L.

See also: ECOMIX® A ECOMIX® P